• 12kV Indoor compressed load break switch
  • 12kV Indoor compressed load break switch
12kV Indoor compressed load break switch
discuss personally
Model
FKN12-12
Basic info
Brand ROCKWILL
Model NO. 12kV Indoor compressed load break switch
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series FKN
Product Detail

Product Overview

The FKN12 - 12D pneumatic load break switch (hereinafter referred to as the load break switch) is an indoor high - voltage switching device for three - phase AC 12kV, 50/60Hz. Under normal circuit conditions, it can close, carry and open load current; it can close short - circuit current and has the ability to carry short - circuit current within a specified time. After the load break switch is equipped with a current - limiting fuse with an impactor, it becomes a load break switch - fuse combined electrical appliance (hereinafter referred to as the combined electrical appliance), which can be used for overload and short - circuit protection of loads (such as power transformers).
This product is suitable for installation in ring main unit switch cabinets, box - type substations and other types of switch cabinets. It is an ideal equipment for the construction, transformation and renewal of current distribution networks, transformation and distribution substations and switch stations.
 
Key Features

Current Handling Capability:Under normal operation, it can smoothly close, carry, and interrupt load current; in the event of a short - circuit fault, it is capable of closing short - circuit current and carrying short - circuit current within the specified time, ensuring short - term stability of the power grid during faults and gaining time for fault elimination.

Combined Protection Feature:When combined with a current - limiting fuse with an impactor, it forms a load break switch - fuse combination electrical appliance, providing overload and short - circuit protection for loads such as power transformers. This simplifies the system protection configuration and enhances the timeliness and effectiveness of protection.

Compact Structure:Based on the pneumatic arc - extinguishing principle, the overall structure is exquisitely designed with a small footprint, suitable for installation in indoor switchgear with limited space.

Flexible Installation:It has strong compatibility with various types of switchgear such as ring main unit switchgear and box - type substations. It can be conveniently installed in both new construction and renovation projects, reducing construction difficulty and costs.

Technical Parameters

Mechanical Characteristics

Operating Environmental Conditions

  •  Altitude: Not exceeding 1000m;
  •  Ambient Temperature: Maximum +40°C, Minimum -25°C;
  • Relative Humidity: Daily average not exceeding 95%, Monthly average not exceeding 90%;
  • Seismic Intensity: Below 8 degrees;
  • This switch should be installed in places free from fire, explosion hazards, severe pollution, chemical corrosion, and violent vibration.
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
What You Need to Know About Load Switch Malfunctions
What You Need to Know About Load Switch Malfunctions
Hey there, I’m Blue — been working as an electrical engineer for more than 20 years now.I’ve spent most of my career designing circuit breakers, managing transformers, and helping power companies solve all sorts of electrical system challenges.Today, a friend from Southeast Asia asked me:"What are the common faults of load switches?"Great question! So let’s break it down in simple terms — no fancy jargon, just real-world stuff you might actually see on the job or during maintenance.First, What E
Master Electrician
06/30/2025
×
Inquiry
Download