• 40.5kV HV Gas Insulated Switchgear GIS
40.5kV HV Gas Insulated Switchgear GIS
discuss personally
Model
ZF28-40.5 /2000-31.5
Basic info
Brand ROCKWILL
Model NO. 40.5kV GIS equipment switchgear (GIS)
Rated voltage 40.5kV
Rated normal current 2000A
Series ZF28
Product Detail

Description:

The 40.5kV GIS equipment represents a new - generation medium - voltage switchgear, evolved from high - voltage 126kV GIS technology. It finds applications in power systems, power generation, rail transit, petrochemicals, metallurgy, mining, building materials, and other large industrial sectors.

Tailored for the retrofit of old air - insulated switchgears, this product undergoes specialized optimization. With a cabinet width ranging from 1200mm to 1680mm and a depth from 2800mm to 3200mm, it enables retrofitting without the need to redo foundations, replace cables, or reinforce load - bearing structures.

Features:

  • Superior Insulation: Boasts a fully enclosed, gas - insulated structure. Eliminates issues like condensation, insulation deterioration - induced discharge, and contact overheating common in air - insulated switchgears.

  • Enhanced Safety & Control: Features a three - position disconnector with an electric mechanism and one - key sequential control. Prevents risks such as manual operation jamming of mobile circuit breakers and avoids tipping - related injuries.

  • Retrofit - Friendly: Ideal for retrofitting old air - insulated switchgears. No need to redo foundations, replace cables, or shut down the entire power station during the process.

  • Advanced Circuit Breaker: Equipped with a self - blasting SF6 circuit breaker. Switching reactive loads won’t cause current interception. Comes with a C2 - level certification report for back - to - back capacitor banks from Xi'an High Voltage Apparatus Research Institute Co., Ltd.

  • User - Adaptable Operation: Retains the operating habits of traditional switchgear products. Operation and maintenance personnel can quickly get accustomed to using this new product.

  • Eco - Friendly Option: Aligns with green environmental protection trends. Offers product solutions with mixed gases.

Technical Parameters:

企业微信截图_17284374895875.png

What is the internal structure of a GIS device?

The GIS conductive circuit is composed of several components. According to the working mode, it can generally be divided into: fixed contact (the electrical contact fastened with fasteners such as screws is called fixed contact, and the fixed contact has no relative movement in the working process. Such as the connection between the contact and the basin, etc.), contact contact (the electrical contact that can be separated in the working process is also called separable contact), sliding and rolling contact (in the working process, the contacts can slide or roll with each other, but the electrical contact that cannot be separated is called sliding and rolling contact. The intermediate contact of the switching appliance is the use of this electrical contact).


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law