The reason why fuses take longer to blow when the input power is higher than normal

Encyclopedia
09/25/2024

When connected to a higher than normal input power supply (voltage), the fuse takes longer to blow, mainly for the following reasons:


The effect of current and voltage relationship


Ohm's law in action


According to Ohm's law (where is the current, is the voltage, is the resistance), in the case of constant circuit resistance, the voltage increase usually leads to an increase in the current. However, for some circuits containing inductors, capacitors and other components, the voltage increase does not necessarily lead to an immediate proportional increase in current.


For example, in a circuit containing inductors, when the voltage is suddenly increased, the inductor will create a reverse electromotive force to block the rapid change in current, making the current rise relatively slowly. This means that for a short period of time, although the voltage is increased, the current may not reach the blown current value of the fuse.


Influence of load characteristics


Different loads respond differently to voltage changes. Some loads have relatively stable current requirements, even if the input voltage increases, the increase in current is more limited. For example, the voltage regulator circuit in some electronic devices will maintain the stability of the output current within a certain range, even if the input voltage rises, it will not increase the current significantly.


For purely resistive loads, such as heaters, an increase in voltage will increase the current proportionally. However, in practice, many circuits are not pure resistive loads, so the effect of voltage rise on current is more complicated.


Factors in the fuse fuse mechanism


Heat accumulation process


A fuse is blown because the heat generated by the passing current exceeds the capacity of the fuse. When the input voltage is increased, although the current may increase, the heat accumulation time required for the fuse to blow will be longer.


Fuses are usually made of metal material with a low melting point, and when an electric current passes through it, heat is generated to raise the temperature of the fuse. A fuse will only blow if the temperature rises enough to melt it. The accumulation of heat is a time process, even if the current increases, it takes a certain amount of time to make the fuse reach the fuse temperature.


For example, a fuse rated for current, at normal operating voltage, may blow within a few seconds when the passing current is exceeded. But if the input voltage rises, assuming the current increases to the point where it may take tens of seconds or even longer to fuse due to the relatively slow heat accumulation rate.


Design characteristics of fuses


The design of fuses usually takes into account a certain overvoltage and overcurrent tolerance. In the case of a voltage rise within a certain range, the fuse will not be blown immediately, but can withstand overvoltage and overcurrent for a period of time to avoid misblowing due to instantaneous voltage fluctuations or brief overcurrent.


For example, some high-quality fuses may have a wide operating voltage range and better resistance to overvoltage, and can still maintain normal operation for a period of time when the input voltage is slightly higher than the normal voltage, without immediately blowing. This is to improve the reliability and stability of the circuit, to avoid frequent replacement of fuses.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
With the increasing complexity of power system operation environment and the deepening of power system reform, traditional power grids are accelerating the transformation to smart grids. The goal of equipment condition-based maintenance is achieved through real-time perception of equipment status by new sensors, reliable communication via modern network technology, and effective monitoring by background expert systems.I. Analysis of Condition-based Maintenance StrategyCondition-based Maintenance
Oliver Watts
06/11/2025
What is the current application status and development trend of medium-voltage switchgear?
What is the current application status and development trend of medium-voltage switchgear?
With the accelerated automation of power equipment, various medium-voltage switchgear have emerged in the market. Classified by insulation media, they are mainly divided into air-insulated, SF₆ gas-insulated and solid-insulated types, each with its own advantages and disadvantages: solid insulation offers good performance but poor environmental friendliness, SF₆ features excellent arc extinguishing capability but is a greenhouse gas, and air insulation has high cost-performance but larger volume
Echo
06/11/2025
What components make up the design of medium-voltage ring network distribution switchgear?
What components make up the design of medium-voltage ring network distribution switchgear?
As an expert who has been deeply engaged in the field of power system design for many years, I have always paid attention to the technological evolution and application practice of medium-voltage ring main distribution equipment. As a core electrical device in the secondary distribution link of the power system, the design and performance of such equipment are directly related to the safe and stable operation of the power supply network. The following is a professional analysis of the key design
Dyson
06/11/2025
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
1. Statistics on Common Faults of Medium-Voltage Switchgear in the Early Operation StageAs project participants, we found during the early operation of a new metro line: 21 sets of power supply equipment were put into use, with a total of 266 accident phenomena in the first year. Among them, 77 faults occurred in medium-voltage switchgear, accounting for 28.9%—significantly higher than faults in other equipment. Statistical analysis shows that major fault types include: protection device s