• LDS135 Current Transformer
LDS135 Current Transformer
discuss personally
Model
LDS135-500/5
Basic info
Brand Wone Store
Model NO. LDS135 Current Transformer
Rated frequency 50/60Hz
Power frequency withstand voltage 3kV
Rated current ratio 500/5
Series LDS
Product Detail

Product Overview

 Double cable Cores Type CT.LDS135 adopts newly high permeability core with high measuring accuracy.Secondary winding fully enclosed vacuum casting in antiflaming plastic shell. It easily installed by making the primary cable through the whole,applied to electrical system cable with highest equipment voltage 0.72,functioning as the tool of current metering , signal collection, relay protection. The current transformer can be executed according to the standard IEC 61869-1:2007 and IEC 61869-2:2012. Or IEC60044-1

Key Features

  • Modular Combination Expansion Capability:Engineered with a modular architecture, the LDS235 supports parallel connection of multiple units to meet ultra-high current measurement requirements. Users can flexibly scale the number of transformers based on actual load current, expanding the transformation ratio beyond 5000/5A while maintaining consistent measurement accuracy.
  • Dynamic Range Expansion Technology:Leveraging advanced magnetic circuit optimization and signal processing algorithms, the LDS135 achieves an industry-leading dynamic response ratio of 1:300. It delivers exceptional linearity from 0.1% of rated current under light loads to 30kA short-circuit fault conditions, ensuring reliable full-spectrum monitoring for power systems.
  • IoT-Integrated Design:Equipped with built-in IoT modules supporting NB-IoT and 4G protocols, the LDS135 seamlessly integrates with smart grid management platforms. Cloud-based remote configuration, real-time data monitoring, and analytics enable maintenance teams to access device status anytime, anywhere, streamlining intelligent and centralized power asset management.
  • Flexible Anti-Shock Structure:Featuring an innovative flexible buffer design with elastic support materials and seismic damping structures, the LDS135 withstands mechanical shocks up to 10G and severe vibrations. Ideal for applications with high vibration requirements such as rail transit systems and offshore wind platforms.

Technical Data

  • Rated secondary current:5A
  • Power frequency withstand voltage:3kV
  • Rated frequency:  50/60Hz
  • Installation site:  Indoor
  • Technical standard:   IEC 60044-1 (IEC 61869-1&2)

Specification

Outline

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis and Handling of Metering Abnormality of 35 kV Outdoor Combined Transformer
Analysis and Handling of Metering Abnormality of 35 kV Outdoor Combined Transformer
1. IntroductionFrequent occurrences of PT burnout and primary - side fuse melting in combined transformers lead to inaccurate energy meter measurement and seriously threaten the safe operation of the power grid. This paper focuses on the repeated PT damage and fuse melting issues of a 35 kV combined transformer, investigates the fault causes, proposes solutions, and recovers the incorrect electricity quantity through correction coefficients. This effectively reduces grid losses and mitigates ser
Felix Spark
07/10/2025
Analysis of an Explosion Accident of a 35 kV Voltage Transformer
Analysis of an Explosion Accident of a 35 kV Voltage Transformer
Voltage transformers (PTs) consist of iron cores and winding coils, working similarly to transformers but with small capacity. They convert high voltage to low voltage for protection, measurement and metering devices, widely used in plants/stations. Classified by insulation: dry - type (≤6 kV), cast - type (indoor 3 - 35 kV), oil - immersed (outdoor ≥35 kV), and SF₆ gas - filled (for combined appliances).During substation operation, accidents from PT electromagnetic resonance or insulation
Felix Spark
07/10/2025
What Tests Does a Qualified Outdoor Current Transformer Need to Pass?
What Tests Does a Qualified Outdoor Current Transformer Need to Pass?
Hey everyone, I’m Oliver, and I’ve been working in current transformer (CT) testing for 8 years.From running around with test equipment on site to now leading full inspection teams, I’ve seen how thousands of outdoor CTs go through a whole series of tests — like going through a military training camp — before they can finally be put into service.A few days ago, a friend asked me:“Oliver, our factory just produced a new batch of outdoor CTs. We’re getting
Oliver Watts
07/09/2025
What should be noted when selecting and installing outdoor current transformers?
What should be noted when selecting and installing outdoor current transformers?
Hey everyone, I'm James, and I've been working with current transformers (CTs) for 10 years.From running around job sites with my mentor, wiring and debugging equipment, to now leading substation projects and handling all kinds of complex CT issues — I’ve worked with a lot of outdoor current transformers over the years. And trust me, I’ve made mistakes, learned from them, and picked up some real-world experience along the way.A few days ago, a fellow engineer asked me:“Ja
James
07/09/2025
What are the methods to reduce the failure rate of outdoor current transformers?
What are the methods to reduce the failure rate of outdoor current transformers?
I. Research Reasons and Background1. Importance of Current TransformersCurrent transformers play the role of current transformation and electrical isolation. They convert the large current of the primary system into a proportional small secondary current, which is supplied to measuring instruments, relay protection, and automatic devices. In the power system, the role of current transformers is irreplaceable and directly plays a key role in the safe and stable operation of the power grid.2. Hars
Felix Spark
07/09/2025
What are the applications of GIS voltage transformers in digital substations?
What are the applications of GIS voltage transformers in digital substations?
Hey everyone, I’m Echo, and I’ve been working with voltage transformers (VTs) for 12 years.From learning how to wire and do error tests under my mentor’s watchful eye, to now participating in all kinds of smart substation projects — I’ve seen the power industry evolve from traditional systems to fully digital ones. Especially in recent years, more and more 220 kV GIS systems are adopting electronic voltage transformers (EVTs), slowly replacing the old-school electro
Echo
07/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!