• LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
LRP Series switching power supply
$22.00
Model
LRS-250-24
LRS-250-12
LRS-200-24
LRS-200-12
LRS-150-24
LRS-150-12
LRS-120-24
LRS-120-12
LRS-100-24
LRS-100-12
LRS-75-24
LRS-75-12
LRS-60-24
LRS-60-12
LRS-50-24
LRS-50-12
LRS-35-24
LRS-35-12
Basic info
Brand Wone Store
Model NO. LRP Series switching power supply
Rated power 250W
Certification CE
Insulation resistance ≥100MΩ(500VDC)
Operating environment -10℃~60℃
Terminal type Threaded type
Wide voltage input range AC100V-260V
rated output of CH1 24V,10A
Wide frequency range 47-63Hz
Series LRP Series
Product Detail

30 - 400W Chassis - type Switching Power Supplies without PFC (with an independent housing for easy installation) have a relatively wide power coverage and a relatively sturdy structure, but lack power factor correction. Their application scenarios are concentrated in fields that are cost - sensitive, have lenient energy efficiency standards, and require a certain degree of protection. 

      ●Industrial auxiliary equipment: Such as control power supplies for small conveyor belts, local lighting systems in workshops, power supply modules for non-precision testing instruments, etc. The casing can provide basic dust and moisture protection, and the scenarios where they are used have a high tolerance for power grid harmonics.

      ●Commercial low-cost equipment: Power supplies inside small commercial refrigerators, vending machines, and simple security monitoring host units, etc. These need to be fixedly installed and have requirements for physical protection of the power supply, but do not need to comply with strict energy efficiency regulations.

      ●Regionally characteristic electromechanical products: Small water pumps in some regions, household dehumidifiers (non-energy-saving models), etc. The casing design meets the equipment integration requirements, and there are no mandatory requirements for power factor locally.

      ●Temporary or outdoor equipment: Power supplies for mobile stage lighting, outdoor temporary power supply boxes (for short-term use), etc. The casing can improve durability, and short-term use has limited impact on the power grid.

It should be noted that their application is limited in regions with strict energy efficiency regulations (such as the EU and North America), and they are not suitable for sharing the power grid with precision electronic equipment to avoid abnormalities caused by harmonic interference.

 

Features:

Wattage:35W-400W

Universal AC Input

Non-PFC, most economical models

Ultra compact and 1U low profile

No load power consumption: 0.2W~0.75W

Operating altitude up to 5000 meters

LED indicator for power on

100% full load burn-in test

2 years warranty

 

selection reference

 

If you need to know about or order switching power supplies of other specifications, Please check the model selection manual.↓↓↓ 

Or you are welcome to contact us.→→→

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the routine tests for outdoor voltage transformers?
What are the routine tests for outdoor voltage transformers?
1. IntroductionOutdoor voltage transformers are key equipment for ensuring the safety of electrical apparatus. Scientific and comprehensive test analysis is required to avoid hazards and property losses caused by improper operation. Test analysis can guide the formulation of operation strategies and precautions, ensure the stable operation of equipment, and maximize economic and social benefits.2. Concept of Outdoor Voltage TransformersAn outdoor voltage transformer is essentially an outdoor ste
Oliver Watts
07/10/2025
Analysis and Handling of Metering Abnormality of 35 kV Outdoor Combined Transformer
Analysis and Handling of Metering Abnormality of 35 kV Outdoor Combined Transformer
1. IntroductionFrequent occurrences of PT burnout and primary - side fuse melting in combined transformers lead to inaccurate energy meter measurement and seriously threaten the safe operation of the power grid. This paper focuses on the repeated PT damage and fuse melting issues of a 35 kV combined transformer, investigates the fault causes, proposes solutions, and recovers the incorrect electricity quantity through correction coefficients. This effectively reduces grid losses and mitigates ser
Felix Spark
07/10/2025
Analysis of an Explosion Accident of a 35 kV Voltage Transformer
Analysis of an Explosion Accident of a 35 kV Voltage Transformer
Voltage transformers (PTs) consist of iron cores and winding coils, working similarly to transformers but with small capacity. They convert high voltage to low voltage for protection, measurement and metering devices, widely used in plants/stations. Classified by insulation: dry - type (≤6 kV), cast - type (indoor 3 - 35 kV), oil - immersed (outdoor ≥35 kV), and SF₆ gas - filled (for combined appliances).During substation operation, accidents from PT electromagnetic resonance or insulation
Felix Spark
07/10/2025
What Tests Does a Qualified Outdoor Current Transformer Need to Pass?
What Tests Does a Qualified Outdoor Current Transformer Need to Pass?
Hey everyone, I’m Oliver, and I’ve been working in current transformer (CT) testing for 8 years.From running around with test equipment on site to now leading full inspection teams, I’ve seen how thousands of outdoor CTs go through a whole series of tests — like going through a military training camp — before they can finally be put into service.A few days ago, a friend asked me:“Oliver, our factory just produced a new batch of outdoor CTs. We’re getting
Oliver Watts
07/09/2025
What should be noted when selecting and installing outdoor current transformers?
What should be noted when selecting and installing outdoor current transformers?
Hey everyone, I'm James, and I've been working with current transformers (CTs) for 10 years.From running around job sites with my mentor, wiring and debugging equipment, to now leading substation projects and handling all kinds of complex CT issues — I’ve worked with a lot of outdoor current transformers over the years. And trust me, I’ve made mistakes, learned from them, and picked up some real-world experience along the way.A few days ago, a fellow engineer asked me:“Ja
James
07/09/2025
What are the methods to reduce the failure rate of outdoor current transformers?
What are the methods to reduce the failure rate of outdoor current transformers?
I. Research Reasons and Background1. Importance of Current TransformersCurrent transformers play the role of current transformation and electrical isolation. They convert the large current of the primary system into a proportional small secondary current, which is supplied to measuring instruments, relay protection, and automatic devices. In the power system, the role of current transformers is irreplaceable and directly plays a key role in the safe and stable operation of the power grid.2. Hars
Felix Spark