• Indoor AC high-voltage vacuum load break switch
Indoor AC high-voltage vacuum load break switch
discuss personally
Model
FZN25A-12/200
Basic info
Brand ROCKWILL
Model NO. Indoor AC high-voltage vacuum load break switch
Rated voltage 12kV
Rated normal current 200A
Rated frequency 50/60Hz
Series FZN
Product Detail

Product Overview

 Indoor AC high-voltage vacuum load switch (hereinafter referred to as load switch) is suitable for three-phase AC 50Hz, 12kV power supply network, as a break load current and close short-circuit current. The product can be equipped with manual and motor operating mechanisms, especially suitable for places with severe conditions, long maintenance cycles and frequent operation requirements.
Vacuum load switch-fuse combination with fuse (hereinafter referred to as combination appliance) FZRN25A-12(D)/T200-31.5 can break the short-circuit current for short-circuit protection. The product has a mechanism tripping, equipped with a fuse with an impactor, when passing the overload current or short-circuit current, the fuse is blown, and the impactor hits the tripping device to make the load switch automatically open to avoid phase loss operation.

Key Features

  • High - efficiency Arc Extinction and Breaking Capacity:Leveraging the high insulation strength and rapid arc - extinction characteristics of the vacuum interrupter, it can quickly extinguish the arc and reliably break load currents, overload currents, and even short - circuit currents under certain conditions. This significantly reduces the ablation of the contacts by the arc and extends the electrical service life of the equipment. For example, in a frequently operated power distribution system, it can stably perform circuit switching operations, reducing the probability of failures.
  • High Insulation Performance:The vacuum environment itself has extremely high insulation performance. Coupled with a reasonable insulation structure design, the indoor AC high - voltage vacuum load break switch can operate reliably in high - voltage environments, effectively preventing phase - to - phase and phase - to - ground short circuits and ensuring the safety and stability of the power system.
  • Fast Switching:Equipped with an advanced operating mechanism, it can achieve fast switching operations with short switching times. It can quickly isolate faulty circuits, reducing the impact of faults on the system. For instance, in the event of a short - circuit fault, it can rapidly cut off the circuit, limit the duration of the short - circuit current, and reduce the risk of equipment damage.

Technical Parameters

 Operating Environmental Conditions

  • Ambient Air Temperature: Maximum +40°C, Minimum -10°C
  • Altitude: Not exceeding 1000m
  • Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90%
  • Seismic Intensity: Less than Grade 8
  • Ambient Air Shall Be Free from Pollution by Corrosive, Flammable Gases, Water Vapor and Other Harmful Gases
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!