• Indoor AC high-voltage vacuum load break switch
Indoor AC high-voltage vacuum load break switch
discuss personally
Model
FZN25A-12/200
Basic info
Brand ROCKWILL
Model NO. Indoor AC high-voltage vacuum load break switch
Rated voltage 12kV
Rated normal current 200A
Rated frequency 50/60Hz
Series FZN
Product Detail

Product Overview

 Indoor AC high-voltage vacuum load switch (hereinafter referred to as load switch) is suitable for three-phase AC 50Hz, 12kV power supply network, as a break load current and close short-circuit current. The product can be equipped with manual and motor operating mechanisms, especially suitable for places with severe conditions, long maintenance cycles and frequent operation requirements.
Vacuum load switch-fuse combination with fuse (hereinafter referred to as combination appliance) FZRN25A-12(D)/T200-31.5 can break the short-circuit current for short-circuit protection. The product has a mechanism tripping, equipped with a fuse with an impactor, when passing the overload current or short-circuit current, the fuse is blown, and the impactor hits the tripping device to make the load switch automatically open to avoid phase loss operation.

Key Features

  • High - efficiency Arc Extinction and Breaking Capacity:Leveraging the high insulation strength and rapid arc - extinction characteristics of the vacuum interrupter, it can quickly extinguish the arc and reliably break load currents, overload currents, and even short - circuit currents under certain conditions. This significantly reduces the ablation of the contacts by the arc and extends the electrical service life of the equipment. For example, in a frequently operated power distribution system, it can stably perform circuit switching operations, reducing the probability of failures.
  • High Insulation Performance:The vacuum environment itself has extremely high insulation performance. Coupled with a reasonable insulation structure design, the indoor AC high - voltage vacuum load break switch can operate reliably in high - voltage environments, effectively preventing phase - to - phase and phase - to - ground short circuits and ensuring the safety and stability of the power system.
  • Fast Switching:Equipped with an advanced operating mechanism, it can achieve fast switching operations with short switching times. It can quickly isolate faulty circuits, reducing the impact of faults on the system. For instance, in the event of a short - circuit fault, it can rapidly cut off the circuit, limit the duration of the short - circuit current, and reduce the risk of equipment damage.

Technical Parameters

 Operating Environmental Conditions

  • Ambient Air Temperature: Maximum +40°C, Minimum -10°C
  • Altitude: Not exceeding 1000m
  • Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90%
  • Seismic Intensity: Less than Grade 8
  • Ambient Air Shall Be Free from Pollution by Corrosive, Flammable Gases, Water Vapor and Other Harmful Gases
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
Testing of Optical Current Transformers (OCT)
Testing of Optical Current Transformers (OCT)
With the development of modern economy and science and technology, photoelectric current transformers (PECTs) have fully transitioned from the trial operation stage to practical application. As a front - line testing personnel, I deeply feel their importance in the power system during daily work. I also realize the necessity of conducting in - depth research on their testing systems and calibration methods. This not only promotes the engineering application of PECTs but also enables the accurate
Oliver Watts
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!