• SS2 Operating Mechainsm For Composite Apparatus
  • SS2 Operating Mechainsm For Composite Apparatus
SS2 Operating Mechainsm For Composite Apparatus
discuss personally
Model
SS2-DS
SS2-SS
Basic info
Brand Wone Store
Model NO. SS2 Operating Mechainsm For Composite Apparatus
Motor Voltage 48V
Series SS2
Product Detail
The range of appliance:

SS2-DS double spring operating mechanism is the operating mechanism of FLRN36B(48)-12D/T100-31.5 indoor AC high voltage SF6 load switch-fuse combination electrical apparatus. It is applicable for XGN15-12 fixed AC metal enclosed cabinet, and it can ensure the safety of the electrical apparatus under total operating model.

Operating instruction

Except the same functions of SS2-口D single spring operating mechanism, Double spring operating mechanism adds a fuse tripping mechanism according to the combination electrical apparatus, leading load switch opening, when fuse is breaking.
Atlention: If changing the same fusion tube for the fuse breaking, please plug the operating handle into the operating hole of the mechanism, anticlockwise rotation, making the transmission of mechanism reset with smaller force, and then, operate by the operating process of the cabinet.

SS2-S boundary dimensions installation dimensions and technical parameter:

SS2 Operating Mechainsm For Composite Apparatus

No.

program name

unit

value

1

rated voltage(motor)

V

DC220V/、110V、 48V. 24V

2

electric operation (energy stored) time

S

≤10

3

average closing speed(with body)

m/s

4.5+1.5

4

average opening speed(with body)

m/s

4.5+1.5

5

the max torque of manual operation

N.m

≤130

6

the max time of activating the release

ms

50-60

7

the power of hitting the release

J

2-5

8

mechanism endurance of the load switch

times

5000

9

mechanism endurance of the grouding switch

times

5000

10

the max attitude of equipment installation

m

2000

11

the max temperature

°C

40

12

the lowest temerature

°C

-25

Fuse tripping mechanism upper and lower holder(new)boundary dimensions:

SS2 Operating Mechainsm For Composite Apparatus






Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!