• AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
  • AC voltage detector pen Tester with vibration mode HLX
AC voltage detector pen Tester with vibration mode HLX
$87.00
Model
VT-1000
VT-1000E
Basic info
Brand Wone
Model NO. UT12E-US UT12E-EU ac voltage detector pen Tester with vibration mode HLX
AC voltage 90V~1000V (high)
Frequency range 50/60Hz
Series VT12E-EU
Product Detail

Dscription

UT12E-EU and UT12M-EU are professional grade voltage detectors. They are designed with IP67 dust/water resistant and can withstand 2 meters drop. These durable devices are great for working in harsh environments. UT12E-EU has an optional vibration mode and UT12M-EU is able to detect magnetic fields.

Feature

Certifications: CE, UKCA, CETLUS

  • Auto power off

  • Buzzer

  • LED indication

  • IP 67

  • AC voltagedetection

  • High/Lowvoltage mode

  • Magnetic solenoiddetection (UT12M-EU)

  • Vibration mode(UT12E-EU)

Specifications

image.png

image.png

How does an AC voltage detector pen tester work?

The primary function of these detectors is to detect the presence of alternating current (AC) voltage and alert the user through visual and auditory signals. Detectors with the HLX vibration mode also feature haptic feedback, allowing for clear perception of voltage presence even in noisy environments.

  • Probe Contact: When the detector's probe comes into contact with electrical wires or equipment, the internal sensing elements (such as a sensing coil) detect changes in the AC electric field.

  • Signal Amplification: The detected weak electrical signal is amplified by the internal amplification circuit.

  • Threshold Detection: The amplified signal is compared with a preset threshold, and an alarm is triggered only if the signal strength exceeds the threshold.

  • Alarm Output: Once voltage exceeding the threshold is detected, the detector alerts the user through LED lights, beeping sounds, and vibration feedback.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What are the polarity test methods for GIS current transformers?
What are the polarity test methods for GIS current transformers?
I’m Oliver, an 8 - year current transformer testing pro. Today, let’s break down new and old polarity test methods for GIS current transformers—how they work and their pros/cons.1.Testing Methods1.1New MethodPre - test ops: Open FDS21/FDS22 fast disconnectors + DS23 disconnector. Close CB21 breaker, then ES21/ES22 grounding disconnectors. Disconnect ES21’s SF6 - shell ground.Wiring: Connect battery between ES21’s moving contact (negative grounded) + ground electrode
Oliver Watts
07/07/2025
Exploring the Design and Application of Photoelectric Current Transformers in GIS
Exploring the Design and Application of Photoelectric Current Transformers in GIS
1.Design and Application Example of Photoelectric Current Transformer in GISThis article takes a 126kV GIS project as a specific example to deeply explore the design ideas and practical application of photoelectric current transformers in the GIS system. Since this GIS project was officially put into operation, the power system has remained stable, with no major failures occurring, and the operation status is relatively ideal.1.1 Design and Application Ideas of Photoelectric Current TransformerI
Dyson
07/07/2025
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
Maintenance and Diagnostic Analysis of Current Transformers in GIS Equipment
I'm Oliver, with 8 years of experience in current transformer testing. These are all practical experiences, shared with you1 Maintenance of Current TransformersHaving been in the business of current transformer testing for 8 years, I know a thing or two about their maintenance! The maintenance of current transformers is divided into minor repairs, intermediate repairs, and major overhauls.Minor repairs mainly involve opening the cover (if necessary) and changing the oil, usually carried out once
Oliver Watts
07/07/2025
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
What are the possible causes of cracking failure in CT terminal blocks within GIS equipment?
Gas - insulated switchgear (GIS) , often called “SF6 combined electrical apparatus”, is widely used in power systems for its high reliability, small footprint, low noise, and low loss. It encloses high - voltage devices like circuit breakers, fast grounding switches, current transformers, and busbars in a grounded metal shell filled withSF6gas. Each device sits in a separate gas chamber with different pressures. The CT terminal block divides gas chambers, connects components, and eas
Felix Spark
07/07/2025
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!