• 40.5kV 72.5kV 126kV 145kV Oil immersed current transformer
  • 40.5kV 72.5kV 126kV 145kV Oil immersed current transformer
40.5kV 72.5kV 126kV 145kV Oil immersed current transformer
discuss personally
Model
LVB-40.5
Basic info
Brand Rockwell
Model NO. LVB Oil immersed current transformer
Rated voltage 40.5kV
Series LVB
Product Detail

Product introduction:
The LVB series current transformers feature oil-impregnated paper insulation and an inverted structure, complying with IEC/IEEE standards. Installed in power lines, these series-connected transformers enable functions including energy measurement, metering, relay protection, and transient protection.

Product features:

  • Robust Primary Winding Design
    The through-type conductive rod structure ensures exceptional dynamic and thermal stability, with a maximum thermal stability current of 63kA/3s (in series configuration).

  • Ultra-Precise Measurement
    The primary winding passes through the center of the secondary winding, eliminating magnetic flux leakage and achieving measurement accuracies of 0.2S and 0.1.

  • Enhanced Secondary Protection
    Secondary windings are encapsulated in an aluminum-shielded housing with organic materials, safeguarding measurement and protection circuits from electrical breakdown.

  • Advanced Capacitor Screen Bushing
    Wound by a high-performance computer-controlled automatic wrapping machine using imported wide-width cable paper, the bushing ensures minimal process variation and excellent insulation. Partial discharge tests are conducted under power frequency voltage to guarantee reliability.

  • German-Made Vacuum Drying Technology
    Utilizing a LEYBOLD imported fully automatic vacuum drying system, the transformer undergoes variable-pressure vacuum drying and oil injection after assembly. Fully imported insulating materials ensure the overall dielectric loss factor (tanδ) remains below 0.3%.

  • Uniform Insulation Wrapping
    The head insulation is applied by an automatic binding machine, ensuring consistent, tight, and uniform wrapping for optimal performance.

  • Weatherproof Secondary Outlet Box
    The one-piece aluminum alloy casting features a dust-proof, waterproof, and breathable sealing structure for reliable outdoor operation.

  • Leakage-Proof Construction
    All component connections use argon arc welding, and the assembly is leak-tested with high-pressure nitrogen, eliminating oil leakage issues typical in oil-immersed products.

  • Corrosion-Resistant Materials
    The shell, base, and junction box are crafted from aluminum alloy, while the expander and nameplate use stainless steel—all exposed parts are rust-proof for lifelong durability.

  • Maintenance-Free Operation
    Designed for minimal upkeep, the transformer reduces long-term operational costs and downtime.

Technical parameter:
LVB Oil immersed current transformer-2.png
Oil immersed current transformer-3.png
Remark: Approximate dimensions and weights for special requirements, please consult us.

Know your supplier
Rockwell
Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.
Main Categories
High voltage/Low voltage/Electrical fittings
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
11 years
Workplace
60000m²
占位
占位
Related Knowledges
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放