• 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
  • 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
$9828.00
Model
C48200
C48200
C48200
C48200
C48100
C48100
C48100
C48100
C4850
C4850
C4850
C4850
Basic info
Brand POWERTECH
Model NO. Rack type energy storage battery
Energy storage capacity 10.24kWh
Cell quality Class A
Series Industrial&Commercial energy storage
Product Detail

DCK-en.png                                    

Peculiarity

  • High energy density.

  • Equipped with BMS battery management system, longer cycle life.

  • Beautiful appearance; Standard rack specifications, free combination, easy installation.

  • The panel integrates a variety of interfaces, supports multiple protocols, and ADAPTS to most photovoltaic inverters and energy storage converters.

  • Can be customized adjustment management battery charging and discharging strategy.

  • Modular design, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months. 

What are the characteristics of rack-mounted energy storage batteries?

  • High integration:All components (such as battery modules, battery management system (BMS), inverter, energy management system (EMS), etc.) are integrated in one or more standard racks, which is convenient for transportation and on-site installation.The racks usually follow certain standard sizes, such as the standard server cabinet with a width of 19 inches.

  • Modular design:The rack-mounted energy storage battery allows users to add or remove specific modules as needed to expand or reduce the capacity of the energy storage system.The energy storage units in each rack can operate independently or be combined into a larger energy storage system in parallel or in series.

  • Standardized interfaces:The rack-mounted design usually adopts standardized interfaces, making components of different brands or models interchangeable or compatible, reducing the difficulty of system integration.

  • Easy installation and maintenance:The rack-mounted design makes the installation of the energy storage system very simple. Only the rack needs to be placed in an appropriate position and necessary electrical connections are made.During maintenance, each module can be easily accessed for inspection or replacement.

  • High space utilization:The design of standard racks can maximize space utilization, enabling the energy storage system to achieve a high energy storage density in a limited space.

  • Remote monitoring and management:The rack-mounted energy storage system usually integrates remote monitoring and management functions, and the system can be monitored and controlled in real time through the Internet or a dedicated network.This characteristic is very important for energy storage applications that require remote operation and maintenance.

  • Environmental adaptability:The rack-mounted design can integrate environmental conditioning equipment such as temperature control and humidity control to ensure that the battery operates under optimal working conditions.The rack itself can also be designed with characteristics such as dustproof and waterproof to improve the environmental adaptability of the system.

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!