• 100kVA Step Down All Copper 3 Phase Dry Type Distribution Transformer
  • 100kVA Step Down All Copper 3 Phase Dry Type Distribution Transformer
  • 100kVA Step Down All Copper 3 Phase Dry Type Distribution Transformer
100kVA Step Down All Copper 3 Phase Dry Type Distribution Transformer
discuss personally
Model
SC(B)-20KV-100KVA
SC(B)-35KV-100KVA
SC(B)-10KV-100KVA
Basic info
Brand Vziman
Model NO. 100KVA Step Down All Copper 3 Phase Dry Type Distribution Transformer
Rated capacity 100kVA
Voltage grade 20KV
Series SC(B)
Product Detail

Feature:

  • The magnetic core has a miter step joint to ensure optimum performance and minimum sound levels by using step lap technology.

  • Windings are cast under vacuum with epoxy resin. Transient analysis tests have been performed to verify the electrical stress distribution.

  • Air-cooling system adopts top-blowing cross flow fan, which has the characteristics of low noise, high wind pressure, beautiful look, etc.

  • Intelligent temperature controller improves the safety and reliability of the transformer.

  • Supply various Enclosure options in IP20, IP23, etc.

Parameter:

image.png

Installation Location:


  • Installed in places without fire, explosion hazard, serious pollution, chemical corrosion and cluster vibration, indoor or outdoor.

  • Supply Ability:500 Set/Sets per Month.

Customized Service:

  • E2 Environmental Class.

  • C2 Climate Class.

  • F1 Fire Resistance Class.


Product Advantages:

  •  Vacuum-Casting

  • Our product is manufactured with vacuum casting process using a metal pattern, producing a thick resin layer with a smooth surface.

  •  Partial Discharge Free

  • Lower partial discharge characteristics.

  • All units are subjected to partial discharge test.

  • Voltage that is twice that of the operating system is applied to ensure safety.

  • Partial discharge is less than 10 pC.

  •  Shop Test Items.

Routine test:

  • Routine test is a must test for all transformers in our workshop.

  • Type test (as requested).

  • Lightning impulse test.

  • Temperature-rise test.

  • Measurement of sound level.


What is a step-down all-copper three-phase dry-type distribution transformer?

Definitions and Characteristics:

  • Voltage Reduction: It means that a transformer converts the input high-voltage electrical energy into low-voltage electrical energy.

  • All-Copper: The windings of the transformer are all made of copper wires, which possess excellent electrical conductivity and mechanical strength.

  • Three-Phase: It indicates that the transformer has three independent windings and is applicable to three-phase alternating current systems.

  • Dry-Type: It means that the transformer does not use a liquid cooling medium (such as transformer oil), and usually adopts natural air cooling or forced air cooling.

Working Principle:

  • Input Voltage: The high-voltage power source is applied to the transformer through the primary winding.

  • Generating Magnetic Field: The current in the primary winding generates an alternating magnetic field in the iron core.

  • Transferring Magnetic Field: The alternating magnetic field is transferred to the secondary winding through the iron core.

  • Inducing Electromotive Force: The alternating magnetic field induces an electromotive force in the secondary winding, generating a low-voltage output voltage.

  • Output Voltage: The secondary winding outputs the required low-voltage electrical energy for the load to use.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放