• Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
  • Iron shell type Intelligent dehumidifier
Iron shell type Intelligent dehumidifier
$41.00
Model
ZCS21M1 60W
ZCS21M2 60W
ZCS21M1 30W
ZCS21M2 30W
ZCS21M1 20W
ZCS21M2 20W
Basic info
Brand Wone Store
Model NO. Iron shell type Intelligent dehumidifier
Rated voltage AC220V+10%
Rated frequency 50/60Hz
Communication port support RS485/RF
Rated power 60W
cabinet type iron plate
Series ZCS21M1/M2
Product Detail

The semiconductor dehumidifier for switchgear is a reliable assistant to safeguard the stable operation of the switchgear, focusing on dealing with the problem of humidity inside the cabinet. In the power system, due to factors such as high environmental humidity and large temperature differences between day and night, the switchgear is prone to condensation inside. Excessive water vapor not only accelerates the corrosion and aging of electrical components, reduces insulation performance, but in severe cases, it may also cause short - circuit faults, threatening the safety and stability of power supply. This dehumidifier uses semiconductor refrigeration technology and operates based on the Peltier effect. The semiconductor refrigeration sheet inside, when powered on, cools rapidly on one side and heats up on the other side. When the humid air inside the switchgear is sucked into the dehumidification air duct by the fan and comes into contact with the cooling surface, the water vapor immediately condenses into liquid water upon cooling and drains out of the cabinet along the water guide pipe. The air passing through the heating surface has a slightly increased temperature and returns to the cabinet in a dry state, avoiding negative impacts caused by temperature differences. The semiconductor dehumidifier for switchgear has multiple practical features. It has low energy consumption, is energy - saving and environmentally friendly, and effectively reduces operating costs. It is small in size, light in weight, and easy to install, and can be flexibly adapted to the spatial layouts of various switchgears. At the same time, some products are equipped with high - precision humidity sensors and intelligent control systems, which can accurately monitor the humidity inside the cabinet in real - time. Once the humidity exceeds the preset safe range, the dehumidification operation is automatically started, and when the humidity reaches the standard, it stops automatically, achieving intelligent and unattended high - efficiency dehumidification, and creating a dry and stable operating environment for the switchgear in all aspects. All series come with a communication function and can be connected to the background monitoring system through the RS485 interface. Maintenance personnel can remotely and real - time monitor the operating status of the dehumidifier and the humidity data inside the cabinet, which is convenient for timely fault diagnosis and maintenance management, further improving the intelligence level and safety of power equipment operation and maintenance.

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr
Felix Spark
07/02/2025
In which directions will dry-type transformers develop in the future?
In which directions will dry-type transformers develop in the future?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From my early days doing commissioning and maintenance in distribution rooms, to later participating in electrical system design and equipment selection for large-scale projects, I’ve witnessed how dry-type transformers have evolved from traditional tools into smarter, greener devices.Recently, a new colleague asked me:“What’s the current state of dry
Echo
07/02/2025
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!