It protects the breaker from being accidentally closed, or the generator from coming on load during the parallel operation. It also protects against voltage loss when machinery is connected to switchboard.
Short circuit protection and, when applicable, single-phase protection are installed. Furthermore, instead of overcurrent protection, an Overload alarm is installed, which is programmed to activate at no less than twice the typical running current.
The following requirements must be accomplished in order for alternators to be properly synchronised.
The incoming machine’s terminal voltage must be about equivalent to the bus-bar voltage.
The incoming machine frequency must be the same as the frequency of the bus-bar.
An additional criterion for 3-phase alternators is that the incoming machine voltages – phase sequence match that of the bus-bars.
A generator is supplying a system through switchgear, and numerous generators are linked in parallel with one generator. When the system is operational, current flows from generators to switchgear.
If one generator fails & its terminal voltage falls under the system voltage, the generator will behave similarly to a motor, & current will flow from switchgear to generator. This is known as reverse power. In the case of a full mechanical failure of generator, effects might range from minor to severe.
Anti-motoring employs reverse power protection. The purpose of this function is to protect the prime mover, not the generator. It has the ability to cut off the prime mover and shut off the fuel supply.
In the event of a partial failure (or) overload of the main supply, a preferred trip is a type of electrical system aboard a ship that is intended to separate the non-essential circuit, or non-essential load, from the main bus bar. As a safety measure, it trips the non-essential loads (like the galley and air conditioning) while allowing the necessary loads to operate (like the steering gear).
It finds faults in the phase to earth connection on a circuit and provides an indication of such faults.
Although reverse current is exceedingly difficult to detect in an alternating current (AC) system, reverse power may be recognised and protected by a reverse power relay.
An electric generator (or) electric motor is made out of a rotor that spins in a magnetic field. Permanent magnets or field coils can generate the magnetic field. In cases of a machine with field coils, a current has to flow through the coils to produce the field; otherwise, no power is delivered to or from the rotor. Excitation is the technique of creating a magnetic field using an electric current.
Residual magnetism is a characteristic in which some excitation persists in the conductor after the magnets are removed.
The frequency of voltage being supplied determines the speed of a standard three-phase induction motor. Changing such motor speed necessitates the construction of a three-phase power frequency converter. This can be accomplished by employing power MOSFETs (or) IGBTs that are capable of high voltages with fast switching speeds.
It checks the alarm circuit’s health on itself. That is, it determines if the power supply to alarm circuit is in good working order and whether all of the relays and contacts are operational.
It is actuated by an undervoltage relay. When there is a power outage, the undervoltage relay detects the loss of voltage and activates the emergency generator. Similarly, when electricity is restored, the relay shuts down the emergency generator.
The primary engine is powered by a shaft generator. It consists of a frequency converter (thyristor operated) that transforms the variable engine speed into a near constant speed and generates electrical power. It can only be used at full speed at sea (not at manoeuvring speed).
Rotary: This method employs rotating diode rectifiers, a primary exciter, and a main exciter.
Static :Brushes and slide rings provide static excitation.
Batteries and generators are the main sources of electrical power within the ship. Batteries stores electrical energy for the immediate use, whereas generators generate power when batteries are depleted.
A ground fault circuit interrupter (GFCI) is used to prevent against electrical shocks by immediately shutting power when it identifies a ground fault (current leakage). It should be fitted in locations where there is a risk of water exposure, such as galley & bathroom outlets.
The proper size of cables assures that electrical circuits are capable of carrying the appropriate current without experiencing excessive voltage drop. Voltage drop may affect device performance and cause wire to overheat.
The maximum current that a circuit breaker may safely sustain determines its ampacity. It is determined by the wire size, insulation type, & component temperature rating. NEC (National Electrical Code) guidelines are often used.
An EPS delivers backup power in condition that the primary power system fails. It is equipped with separate generators, distribution panels, & key loads to make certain that important systems like as navigation and safety continue to function.
To prevent galvanic corrosion, marine electrical systems require consideration for the corrosive effects of seawater, vibration, and the necessity for isolation. Because of the potentially dangerous surroundings, they also demand additional safety procedures.
Harmonic distortion analysis is essential for protecting sensitive equipment. Among the techniques for mitigation include the use of
Harmonic filters,
Proper grounding, and
Use of equipment constructed
to manage harmonic loads.
Generators,
Batteries,
Switchboards, and
Wiring
are the essential components of a maritime electrical system.
Generators generate power, batteries store it, switchboards transmit it to various areas of the vessel, and cabling connects each of the components.
Corrosion,
Vibration, and
Moisture
are some of the most typical problems that occur with maritime electrical systems.
Corrosion may harm electrical connections & wiring,
Vibration and moisture might cause wires to break.
A range of instruments and procedures, including as voltage testers, continuity testers, & circuit diagrams, can be used to diagnose marine electrical problems.
When different metals get into electrical contact with one another in a salt-water atmosphere, galvanic corrosion can occur which damages the metal. Use
Sacrificial anodes,
Separate dissimilar metals, &
Installing corrosion-resistant parts
in requirements to prevent it.