Bundled Conductors Used in Transmission Line

Electrical4u
03/22/2024

What Are Bundled Conductors Used In Transmission Line

Single stranded conductors are used in transmission system usually up to 220 KV. But it is not possible to use single-stranded conductor for the voltage above 220 KV systems. For very high voltage system, hollow conductor can be used to optimize the flow of current through it. But erection and maintenance of hollow conductors in the ∑HV system are not economical. The problem can be solved by using bundled conductors instead of hollow conductor in the electrical transmission system above 220 KV voltage level.

What is Bundled Conductor?

We call bundled conductor to those conductors which form from two or more stranded conductors, bundled together to get more current carrying capacity.

Here, we use two or more stranded conductors per phase. Also, to increase the current carrying capacity of the system, a bundle conductor also contributes various facilities to the electrical transmission system. A bundled conductor reduces the reactance of the electric transmission line. It also reduces voltage gradient, corona loss, radio interference, surge impedance of the transmission lines.
By making bundle conductor, the geometric mean radius (GMR) of the conductor increased. As the self GMR of the conductor increases, the
inductance of the conductor decreases. Theoretically, there is an optimum sub-conductor spacing in bundle conductor that will give minimum voltage gradient on the surface of bundle conductor. The optimum spacing between sub-conductors for reducing voltage gradient is eight to ten times of the diameter of the conductor.

Since the voltage gradient gets reduced, the radio interference also gets reduced.
As the inductance of the bundled conductor is reduced, the surge impedance of the line is reduced became the formula of surge impedance is

Where L is the inductance per phase per unit length, and C is the capacitance per phase per unit length of the transmission line. As the surge impedance gets reduced due to bundling the conductor, the surge impedance loading, of the conductor gets increased. Increased surge impedance loading makes the transmission capacity of the system more.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Ground Wire in Overhead Transmission LinesThe ground wire (also called earth wire or OPGW) installed above phase lines in overhead transmission lines acts as a key protective and safety component. It provides lightning protection, ground fault defense, and helps prevent electrical system disruptions.In overhead transmission lines, positioning the ground wire above phase lines serves specific safety and performance purposes. Referred to as a "shield wire" or "static wire," this configuration has
Edwiin
06/04/2025
What is the Power Angle in a Power Transmission Line?
What is the Power Angle in a Power Transmission Line?
The power angle, denoted by δ, is the phase angle difference between two voltage levels in a power transmission line. Specifically, it represents the angular discrepancy between the sending-end voltage phasor and the receiving-end voltage (or between voltages at two bus points). In simpler terms, it quantifies the phase shift between voltage and current waveforms in the transmission line.Also referred to as the torque angle or load angle, this parameter is critical for two key reasons: it
Edwiin
06/04/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!