Is there a correlation between the size of the circuit breaker and its strength?

Encyclopedia
09/28/2024

There is indeed a correlation between the size of the circuit breaker (which usually refers to its rated current, which is the number of amps) and its strength (which is its ability to protect). The size selection of the circuit breaker should be based on the specifications of the wires in the circuit and the expected maximum load current. Here's a detailed explanation:


The relationship between circuit breaker size and strength


Protection ability


The size (rated current) of the circuit breaker determines the maximum current it can withstand. When the current exceeds the rated value of the circuit breaker, the circuit breaker will trip, cutting off the power supply, thereby protecting the circuit from overcurrent or short circuit damage.


Selection basis


The selection of circuit breakers is usually based on the current carrying capacity of the wires in the circuit (i.e. the maximum current that the wires can safely carry). The rated current of the circuit breaker should not be greater than the carrying capacity of the wire to ensure that the wire will not overheat or fuse due to overcurrent.


Relationship between smaller wires and high amperage circuit breakers under the same load


It is inappropriate and unsafe to use a smaller diameter (cross-sectional area) wire with a higher amperage circuit breaker under the same load. Here's why:


Overload risk


Thinner wires have lower carrying capacity. If a circuit breaker with a high amperage is used, the wire may overheat or even fuse when the current exceeds the current carrying capacity of the wire but does not reach the breaker trip threshold, resulting in safety accidents such as fire.


Protection mismatch


The level of protection between the wire and the circuit breaker should match. If the rated current of the circuit breaker is higher than the carrying capacity of the wire, the circuit breaker will not trip in time when the current exceeds the safe carrying capacity of the wire, thus losing its protective effect.


The right way to pair


In order to ensure the safety of the circuit, the following steps should be followed to select the appropriate wire and circuit breaker:


Determined load current


The required current is calculated from the maximum expected load in the circuit.


Choose the right wire


Select a wire with sufficient carrying current according to the load current. The cross-sectional area of the wire should at least be able to withstand the maximum expected current in the circuit.


Select the appropriate circuit breaker


The rated current of the circuit breaker should be slightly greater than or equal to the carrying current of the wire, but not too large to ensure that the circuit breaker can cut off the power supply in time when the wire is overloaded.


Give an example


Suppose you have A circuit where the maximum expected load current is 15 amps (A) :


Select wire


Select a wire with at least 15A carrying capacity. For example, AWG 14 wire can normally carry 15A of current.


Select circuit breaker


Select a circuit breaker with a rated current of 15A or slightly greater. For example, a circuit breaker of 15A or 20A can be selected, but it is not recommended to choose a circuit breaker greater than 20A, because this may cause the wire to overload.


Sum up


There is a close correlation between the size of the circuit breaker and its strength, and the correct pairing can ensure the safety of the circuit. Smaller diameter wires should not be used with higher amperage circuit breakers under the same load, as this increases the risk of overload and can lead to safety incidents. For the safe operation of the circuit, the matching of the wire and circuit breaker should be selected based on the load current and the carrying capacity of the wire.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!