Thermal Relay Working Principle Construction of Thermal Overload Relay

Electrical4u
03/26/2024

What Is A Thermal Relay

The coefficient of expansion is one of the basic properties of any material. Two different metals always have different degree of linear expansion. A bimetallic strip always bends when it heated up, due to this inequality of linear expansion of two different metals.

Working Principle of Thermal Relay

A thermal relay works depending upon the above mentioned property of metals. The basic working principle of thermal relay is that, when a bimetallic strip is heated up by a heating coil carrying over current of the system, it bends and makes normally open contacts.

Construction of Thermal Relay

The construction of thermal relay is quite simple. As shown in the figure above the bimetallic strip has two metals – metal A and metal B. Metal A has lower coefficient of expansion and metal B has higher coefficient of expansion.

When over current flows through the heating coil, it heats up the bimetallic strip.
Due to the heat generated by the coil, both of the metals are expanded. But expansion of metal B is more than expansion of metal A. Due to this dissimilar expansion the bimetallic strip will bend towards metal A as shown in the figure below.
thermal relay

thermal relay
The strip bends, the NO contact is closed which ultimately energizes the trip coil of a circuit breaker.
The heating effect is not instantaneous. As per Joule’s law of heating, the amount of heat generated is

Where, I is the over current flowing through the heating coil of thermal relay.
R is the electrical resistance of the heating coil, t is the time for which the current I flows through the heating coil. Hence from the above equation it is clear that, heat generator by the coil is directly proportional to the time during which the over current flows through the coil. Hence there is a prolonged time delay in the operation of thermal relay.

That is why this type of relay is generally used where over load is allowed to flow for a predetermined amount of time before it trips. If overload or over current falls down to normal value before this predetermined time, the relay will not be operated to trip the protected equipment.
A typical application of thermal relay is overload protection of electric motor.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Ground Wire in Overhead Transmission LinesThe ground wire (also called earth wire or OPGW) installed above phase lines in overhead transmission lines acts as a key protective and safety component. It provides lightning protection, ground fault defense, and helps prevent electrical system disruptions.In overhead transmission lines, positioning the ground wire above phase lines serves specific safety and performance purposes. Referred to as a "shield wire" or "static wire," this configuration has
Edwiin
06/04/2025
What is the Power Angle in a Power Transmission Line?
What is the Power Angle in a Power Transmission Line?
The power angle, denoted by δ, is the phase angle difference between two voltage levels in a power transmission line. Specifically, it represents the angular discrepancy between the sending-end voltage phasor and the receiving-end voltage (or between voltages at two bus points). In simpler terms, it quantifies the phase shift between voltage and current waveforms in the transmission line.Also referred to as the torque angle or load angle, this parameter is critical for two key reasons: it
Edwiin
06/04/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!