Why does the overload relay trip in a fridge compressor?

Encyclopedia
09/30/2024

Overload Relay trips in refrigerator compressors are usually done to protect the compressor from damage. The function of the overload relay is to cut off the power supply when the current is too large to prevent overheating or damage to the compressor. Here are some common causes of overload relay trip:


Overload


  • Difficulty in starting: If the compressor experiences difficulty in starting, it may cause excessive instantaneous current, which can trigger the overload relay.


  • Continuous high load: If the compression is operated under high load for a long time, it will also cause the current to increase, exceeding the safety range set by the relay.


Electrical fault


  • Short circuit: If there is a short circuit in the compressor or the related circuit, the current will increase abnormally, and the overload relay will trip.


  • Grounding fault: If the circuit is poorly grounded, it may also cause current instability, resulting in relay operation.


Excessive temperature


  • Poor heat dissipation: If poor ventilation around the compressor or a blocked radiator causes the compressor temperature to be too high, the overload relay may trip to protect the compressor.


  • Refrigerant problem: Insufficient or too much refrigerant will affect the normal operation of the compressor, resulting in overheating or excessive current.


Mechanical failure


  • Compressor stuck: If the internal parts of the compressor are stuck or seriously worn, it will cause difficulty in starting or excessive current during operation.


  • Piston stuck: The piston stuck in the cylinder will also cause the compressor to not work properly.


Control circuit problem


  • Relay failure: The relay itself may fail, resulting in misoperation.


  • Poor contact: Poor contact between the compressor and other circuit connections may also cause overload protection.


Solution


When the overload relay tripping, should first cut off the power, and then investigate the specific cause. You can check by following these steps:


Inspection compressor


  • Confirm whether the compressor can rotate freely to eliminate mechanical stuck problems.


  • Check whether the compressor is overheated, clean the dust and debris around the compressor, and ensure good ventilation conditions.


Inspection circuit


  • Use a multimeter to check whether the circuit is short or open.


  • Check whether the power supply voltage is stable and eliminate the impact of voltage fluctuations on the compressor.


Check refrigeration system


  • Check whether the refrigerant is sufficient, and eliminate leakage or excessive refrigerant.


  • Check that the evaporator and condenser are clean to ensure good heat exchange efficiency.


Check relay


Check whether the relay is working properly and replace it with a new relay if necessary.If the problem cannot be solved after the above inspection, it is recommended to contact professional maintenance personnel for diagnosis and repair to avoid greater losses due to incorrect operation.




Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What is Automatic Voltage Regulator?
What is Automatic Voltage Regulator?
An automatic voltage regulator is employed to regulate voltage, converting fluctuating voltages into a constant one. Voltage fluctuations mainly stem from variations in the load on the supply system. Such voltage variations can damage the equipment within the power system. These fluctuations can be mitigated by installing voltage - control equipment at various locations, such as near transformers, generators, and feeders. Multiple voltage regulators are often placed throughout the power system t
Edwiin
05/22/2025
What is Static Voltage Regulator?
What is Static Voltage Regulator?
Types of Static Voltage RegulatorThe static voltage regulator is superior to electromechanical regulators in respect of the accuracy of control, response, reliability and maintenance. The static voltage regulator is mainly classified into two types. They are;Servo Type Voltage RegulatorMagnetic Amplifier RegulatorThe types of static voltage regulator are described below in details;Servo Type Voltage RegulatorThe main feature of the servo type voltage regulator is the use of the amplidyne. The am
Edwiin
05/21/2025
What is Arc Extinction Circuit Breaker?
What is Arc Extinction Circuit Breaker?
When the current-carrying contacts of a circuit breaker separate, an arc forms and persists briefly after contact separation. This arc is hazardous due to the heat energy it generates, which can produce explosive forces.A circuit breaker must extinguish the arc without damaging equipment or endangering personnel. The arc significantly influences the breaker’s performance. Interrupting aDC arcis inherently more challenging than anAC arc. In an AC arc, the current naturally reaches zero duri
Edwiin
05/20/2025
Air Break Circuit Breaker
Air Break Circuit Breaker
In an air break circuit breaker, the arc is initiated and extinguished in substantially static air as the arc moves. These breakers are used for low voltages, generally up to 15 kV, with rupturing capacities of 500 MVA. As an arc-quenching medium, air circuit breakers offer several advantages over oil, including:Elimination of risks and maintenance associated with oil use.Absence of mechanical stress caused by gas pressure and oil movement.Elimination of costs from regular oil replacement due to
Edwiin
05/20/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!