Safety Rules for Overhead Lines

Electrical4u
03/30/2024

Safety Rules For Overhead Lines

  • Nobody should climb any tower carrying live overhead conductors.

  • Cows or other domestic animals should not be tied with any tower legs and stay wires.

  • Nobody should be allowed to throw any metallic strip, metallic wire, ropes and green twinges to the live over head lines.

  • If any conductor is snapped or dangling from the tower, should not be touched without proper shutdown and temporary earthing arrangement. In this case nobody should be allowed to come closer to the snapped or hanged conductor until the entire circuit is isolated and earthed from both ends substations. In additions to that the snapped conductors should also be locally temporarily earthed with proper earthing rod before touching it for repairing work.

  • If we see any sparking on the live conducting parts of over head system, we should immediately inform to the concerned authority.

  • We should not put any temporary or permanent bands or embankments under the live over head line which is causes reduction in ground clearance of the Overhead line.

  • We should not carry any long metallic poles, bamboos, pipes etc below the live conductors. Farming just below the over head electrical lines are allowed but cultivation of sugarcanes like plants h be avoided if those grow above 5 meters height.

  • Over loaded bullock carts, tractors trail or similar kind of vehicle with height more than 5 meters from ground level should not cross any live over head lines.

  • Any building either temporary or permanent should not be constructed below the over head line. Not only below the over head lines, the building should also be constructed well away from the line by following standard electrical clearance rules of the country.

  • We should not touch any over head tower body during rain.

  • We should keep sufficient safe distance from the over head line during stormy weather. During storm, any line conductor or tower may accidentally fall on us.


Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Ground Wire in Overhead Transmission LinesThe ground wire (also called earth wire or OPGW) installed above phase lines in overhead transmission lines acts as a key protective and safety component. It provides lightning protection, ground fault defense, and helps prevent electrical system disruptions.In overhead transmission lines, positioning the ground wire above phase lines serves specific safety and performance purposes. Referred to as a "shield wire" or "static wire," this configuration has
Edwiin
06/04/2025
What is the Power Angle in a Power Transmission Line?
What is the Power Angle in a Power Transmission Line?
The power angle, denoted by δ, is the phase angle difference between two voltage levels in a power transmission line. Specifically, it represents the angular discrepancy between the sending-end voltage phasor and the receiving-end voltage (or between voltages at two bus points). In simpler terms, it quantifies the phase shift between voltage and current waveforms in the transmission line.Also referred to as the torque angle or load angle, this parameter is critical for two key reasons: it
Edwiin
06/04/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!