What Is Hartley Oscillator

What is a Hartley Oscillator?

A Hartley Oscillator (or RF oscillator) is a type of harmonic oscillator. The oscillation frequency for a Hartley Oscillator is determined by an LC oscillator (i.e. a circuit consisting of capacitors and inductors). Hartley oscillators are typically tuned to produce waves in the radiofrequency band (which is why they are also known as RF oscillators).

Hartley Oscillators were invented in 1915 by American engineer Ralph Hartley.

The distinguishing feature of a Hartley oscillator is that the tuning circuit consists of a single capacitor in parallel with two inductors in series (or a single tapped inductor), and the feedback signal needed for oscillation is taken from the center connection of the two inductors.

A circuit diagram for a Hartley Oscillator is shown below in Figure 1:
hartley oscillator

Here the RC is the collector resistor while the emitter resistor RE forms the stabilizing network. Further the resistors R1 and R2 form the voltage divider bias network for the transistor in common-emitter CE configuration.

Next, the capacitors Ci and Co are the input and output decoupling capacitors while the emitter capacitor CE is the bypass capacitor used to bypass the amplified AC signals. All these components are identical to those present in a common-emitter amplifier which is biased using a voltage divider network.

However, Figure 1 also shows one more set of components viz., the inductors L1 and L2, and the capacitor C which form the tank circuit (shown in the red enclosure).

On switching ON the power supply, the transistor starts to conduct, leading to an increase in the collector current, IC which charges the capacitor C.

On acquiring the maximum charge feasible, C starts to discharge via the inductors L1 and L2. These charging and discharging cycles result in the damped oscillations in the tank circuit.

The oscillation current in the tank circuit produces an AC voltage across the inductors L1 and L2 which are out of phase by 180o as their point of contact are grounded.

Further from the figure, it is evident that the output of the amplifier is applied across the inductor L1 while the feedback voltage drawn across L2 is applied to the base of the transistor.

Thus one can conclude that the amplifier’s output is in-phase with the tank circuit’s voltage and supplies back the energy lost by it while the energy fed back to the amplifier circuit will be out-of-phase by 180o.

The feedback voltage which is already 180o out-of-phase with the transistor, is provided by an additional 180o phase-shift due to the transistor action.

Hence the signal which appears at the transistor’s output will be amplified and will have a net phase-shift of 360o.

At this state, if one makes the gain of the circuit to be slightly greater than the feedback ratio given by

(if the coils are wound on the same core with M indicating the mutual inductance)
then the circuit generates the oscillator that can be sustained by maintaining the circuit’s gain to be equal to that of the feedback ratio.

This causes the circuit in Figure 1 to act as an oscillator as it would then satisfy both the conditions of the Barkhausen criteria.

The frequency of such an oscillator is given as

Where,

Hartley oscillators are available in many different configurations including series-or shunt-fed, common-emitter or common-base configured, and BJT (Bipolar Junction Transistor) or FET (Field Effect Transistor) amplifier based.

Further, it is to be noted that the transistor-based amplifier section of Figure 1 can even be replaced by an amplifier of any other kind like that of an inverting amplifier formed by an Op-Amp as shown by Figure 2.

The working of this kind of oscillator is similar to that of the one shown earlier. However, here, the oscillator’s gain can be individually adjusted using the feedback resistor Rf due to the fact that the gain of the inverting amplifier is given as -Rf / R1.

From this, it can be noted that, in this case, the gain of the circuit is less dependent on the circuit elements of the tank circuit.

This increases the stability of the oscillator in terms of its frequency.
hartley oscillator using an op-amp
Hartley Oscillators are advantageous as they are easy-tunable circuits with very few components including a capacitor and either two inductors or a tapped coil.

This results in a constant amplitude output throughout its wide operational frequency r, ranging from 20 kHz to 30 MHz. However, this kind of oscillator is not suitable for low frequency as it would result in a large-sized inductor which makes the circuit bulky.

Further, a Hartley Oscillator’s output has high harmonics content in it and hence does not suit the applications that require pure sine wave.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Ground Wire in Overhead Transmission LinesThe ground wire (also called earth wire or OPGW) installed above phase lines in overhead transmission lines acts as a key protective and safety component. It provides lightning protection, ground fault defense, and helps prevent electrical system disruptions.In overhead transmission lines, positioning the ground wire above phase lines serves specific safety and performance purposes. Referred to as a "shield wire" or "static wire," this configuration has
Edwiin
06/04/2025
What is the Power Angle in a Power Transmission Line?
What is the Power Angle in a Power Transmission Line?
The power angle, denoted by δ, is the phase angle difference between two voltage levels in a power transmission line. Specifically, it represents the angular discrepancy between the sending-end voltage phasor and the receiving-end voltage (or between voltages at two bus points). In simpler terms, it quantifies the phase shift between voltage and current waveforms in the transmission line.Also referred to as the torque angle or load angle, this parameter is critical for two key reasons: it
Edwiin
06/04/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!