A Temperature Transducer is a device that converts the thermal quantity into any physical quantity such as mechanical energy, pressure and electrical signals etc. For example, in a thermocouple the electrical potential difference is produced due to temperature difference across its terminals. So, thermocouple is an temperature transducer.
The input to them are always the thermal quantities
They generally converts the thermal quantity into electrical quantity
They are usually used for the measurement of the temperature and heat flow
The basic scheme of temperature transducers is given below in following steps
Sensing Element.
The sensing element in the temperature transducers is the element whose properties change with change in temperature. As the temperature changes the corresponding change occurs in certain property of the element.
Example – In a Resistance Temperture Detector (RTD) the sensing element is the Platinum metal.
Desirable Conditions for Choosing the Sensing Element are as
Change per unit resistance of material per unit change in temperature should be large
The material should have a high resistivity so that minimum volume of material is used for its construction
The material should have continuous and stable relationship with temperature
Transduction Element
It is the element that transforms the output of the sensing element into electrical quantity. The change in the property of the of sensing element acts as the output for it. It measures the change in the property of sensing element. The output is of transduction element is then calibrated to give output which represents the change in the thermal quantity.
Example- In the thermocouple the potential difference produced across the two terminal is being measured by voltmeter and magnitude of voltage produced after calibration gives idea of change in temperature.
In these the sensing element is in direct contact with the thermal source. They use the conduction for transfer of thermal energy.
In a non-contact temperature sensor, the element is not in direct contact with the thermal source (analogous to a non contact voltage tester or voltage pen). Non-contact temperature sensors use principle of convection for heat flow. Various temperature transducers that are generally used are described below:
The word thermistor can be termed as Thermal Resistor. So as the name indicates it is a device whose resistance changes with the change of the temperature. Due to there high sensitivity they are widely used for the measurements of the temperature.They are usually called the ideal temperature transducer. Thermistors are generally composed of mixture of metallic oxides.
They have Negative Thermal Coefficient i.e. resistance of the thermistor decreases with increase in temperature
They are made up of the semiconductor materials
They are made sensitive than RTD (Resistance Thermometres) and Thermocouples
There resistance lies between 0.5Ω to 0.75 MΩ
They are generally used in applications where measurement range of temperature -60oC to 15oC.
Another type of temperature transducer is the Resistance Temperature Detector or RTD. RTD’s are precision temperature sensors made from high-purity conducting metals such as platinum, copper or nickel wound into a coil and whose electrical resistance changes as change of temperature, similar to that of the thermistor.
There resistance changes with following relation as,
R = Resistance of element at given temperature
α = Thermal coefficient of element
Ro = Resistance of element at 0oC
They are highly sensitive and very cheap as compared to thermistors and thermocouples
They can measure the temperature from -182.96oC to 630.74oC
Thermocouples are temperature transducers that are basically consists of two junctions of dissimilar metals, such as copper and constantan that are welded. One junction is kept at a constant temperature called the reference (Cold) junction, while the other the measuring (Hot) junction. When the two junctions are at different temperatures, a voltage is developed across the junction which is used to measure the temperature.
When the junctions of two metals such as copper and constantan are connected together the potential difference is produced is produced between them. The phenomenon is called the Seebeck effect as a temperature gradient is generated along the conducting wires producing an emf. Then the output voltage from a thermocouple is a function of the temperature changes.
Extreme temperatures of range between -200oC to over +2000oC can be measured with thermocouples which is an advantage over both RTD and Thermistor
They are the Active Transducers so they don’t require any external source for measuring of temperature as like RTD’s and Thermistors.
They are the cheaper than both RTD’s and Thermistors.
These have small accuracy as compared to RTD’s and Thermistors so generally they are not used for high precision work.
These are the temperature transducers which use the temperature sensing element with monolithic electronic circuits as a combination for the measurement of temperature.
They have following type
LM 335 – it provides an output of 10 mV/oK
LM 34 – it provides an output of 10 mV/oF
AD 592 – it provides a current output of 1µA/oK
A LM335 is an temperature sensitive zener diode, which reverse biased into its breakdown region when sensor senses any temperature changes and gives output as,
θ = Temperature in oC
They are linear temperature transducers
They are very cheap
They have operating range is small between 0 – 200oC which is the main disadvantage of them.