What are the Types of Overhead Conductor ?

Encyclopedia
09/05/2024


What are the Types of Overhead Conductor ?


Overhead Conductor Definition


An overhead conductor is defined as a physical medium used to carry electrical energy across distances in transmission and distribution systems.


Copper vs. Aluminum Conductors


Aluminum conductors are preferred over copper due to cost efficiency and reduced corona discharge, despite having lower conductivity and tensile strength.


Types of Conductors


Overhead conductors include AAC, ACAR, AAAC, and ACSR, each with unique properties and uses.


AAC Characteristics


  • AAC has lower strength and more sag per span length than other conductors, making it suitable for shorter spans at the distribution level.


  • It has slightly better conductivity at lower voltages than ACSR.


  • The cost of AAC is similar to that of ACSR.


ACAR (Aluminium Conductor, Aluminium Reinforce)


  • It is cheaper than AAAC but pro to corrosion.

  • It is most expansive.


AAAC (All Aluminium Alloy Conductor)


d1554b4fefb06702b73edf3635bbfe6c.jpeg


  • It has same construction as AAC except the alloy.


  • Its strength is equal to ACSR but due to absence of steel it is light in weight.


  • The presence of formation of alloy makes it expensive.


  • Due to stronger tensile strength than AAC, it is used for longer spans.

  • It can be used in distribution level i.e. river crossing.

  • It has lesser sag than AAC.


The difference between ACSR and AAAC is the weight. Being lighter in weight, it is used in transmission and sub-transmission where lighter support structure is required such as mountains, swamps etc.


ACSR (Aluminium Conductor Steel Reinforced)


6369fd0f1af7e16c854109a4fc6a1935.jpeg


  • ACSR is used for longer spans while minimizing sag. It may consist of 7 or 19 steel strands surrounded by aluminum strands.


  • The number of strands is represented by x/y/z, where ‘x’ is the number of aluminum strands, ‘y’ is the number of steel strands, and ‘z’ is the diameter of each strand.


  • Strands provide flexibility, prevent breakage and minimize skin effect.


  • The number of strands depends on the application, they may be 7, 19, 37, 61, 91 or more.


  • If the Al and St strands are separated by a filler such as paper then this kind of ACSR is used in EHV lines and called expanded ACSR.


  • Expanded ACSR has larger diameter and hence lower corona losses.



IACS (International Annealed Copper Stand)


It is 100% pure conductor and it is standard for reference.

 

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Why is the Ground Wire Always Positioned Above the Overhead Power Lines?
Ground Wire in Overhead Transmission LinesThe ground wire (also called earth wire or OPGW) installed above phase lines in overhead transmission lines acts as a key protective and safety component. It provides lightning protection, ground fault defense, and helps prevent electrical system disruptions.In overhead transmission lines, positioning the ground wire above phase lines serves specific safety and performance purposes. Referred to as a "shield wire" or "static wire," this configuration has
Edwiin
06/04/2025
What is the Power Angle in a Power Transmission Line?
What is the Power Angle in a Power Transmission Line?
The power angle, denoted by δ, is the phase angle difference between two voltage levels in a power transmission line. Specifically, it represents the angular discrepancy between the sending-end voltage phasor and the receiving-end voltage (or between voltages at two bus points). In simpler terms, it quantifies the phase shift between voltage and current waveforms in the transmission line.Also referred to as the torque angle or load angle, this parameter is critical for two key reasons: it
Edwiin
06/04/2025
Comparison Between Overhead & Underground Transmission Systems
Comparison Between Overhead & Underground Transmission Systems
Key Differences and Comparison Between Underground and Overhead Power Transmission & DistributionPublic SafetyIn terms of public safety, underground systems outperform overhead transmission systems. With all transmission and distribution components buried, underground setups minimize risks from obstacles and external interference. Additionally, they are less susceptible to environmental factors like wind, storms, and heavy rain, making them inherently more secure.Initial CostUnderground syst
Edwiin
05/30/2025
Charging Current in Transmission Line
Charging Current in Transmission Line
Charging Current in Transmission LinesIn a transmission line, air serves as the dielectric medium between conductors. When voltage is applied to the sending end, current begins to flow between conductors due to the imperfect insulating properties of the dielectric. This current is known as the charging current of the transmission line.In other words, the current associated with the line capacitance is defined as the charging current. The magnitude of charging current depends on the line voltage,