What are harmonics in electrical systems, and what causes them?

Encyclopedia
03/13/2025

In an electrical system, harmonics refer to the components with frequencies that are integer multiples greater than the fundamental frequency obtained by decomposing a periodic non-sinusoidal alternating quantity through Fourier series, and they are usually called higher harmonics.

The main causes of harmonics are as follows:

  • Existence of Nonlinear Loads: This is the primary cause of harmonics generation. For example, power electronic devices, including rectifiers, inverters, and frequency converters, the semiconductor devices inside will distort the current and voltage waveforms during operation, generating harmonics. Take a rectifier as an example. It converts alternating current into direct current. During the conversion process, the input current will show a non-sinusoidal waveform and contain a large number of harmonic components. In addition, equipment such as arc furnaces and fluorescent lamps are also common nonlinear loads. In the process of steelmaking in an arc furnace, the instability of the arc will lead to current fluctuations and generate harmonics. Due to the function of the ballast in a fluorescent lamp, the current waveform will also be distorted, generating harmonics.

  • Excitation Current of Transformers: When a transformer is in operation, magnetic saturation will occur in its iron core, resulting in the excitation current no longer being a sinusoidal wave, thus generating harmonics. Especially when the transformer is switched on without load or operating under a light load, the harmonic components in the excitation current will be more obvious.

  • Unbalance of the Power Supply System: When the loads of each phase in a three-phase power supply system are unbalanced, it will lead to the asymmetry of the current and voltage, thus generating harmonics. For example, in some industrial sites, due to the different equipment connected to each phase, the situation of three-phase load unbalance may occur, causing harmonics to appear in the power supply system.

Harmonics can cause increased heating and greater losses in electrical equipment, affecting the normal operation and service life of the equipment. They may also interfere with communication systems and trigger resonances in the power system and other issues. Therefore, corresponding measures need to be taken for treatment.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
Why 3-Phase Power? Why Not 6, 12 or More for Power Transmission?
It is well-known that single-phase and three-phase systems are the most prevalent configurations for power transmission, distribution, and end-use applications. While both serve as fundamental power supply frameworks, three-phase systems offer distinct advantages over their single-phase counterparts.Notably, multi-phase systems (such as 6-phase, 12-phase, etc.) find specific applications in power electronics—particularly in rectifier circuits and variable frequency drives (VFDs)—wher
Edwiin
06/05/2025
How Many Poles and Towers are Situated Within a 1-km Span?
How Many Poles and Towers are Situated Within a 1-km Span?
The number of distribution poles and transmission towers within a 1-kilometer stretch of overhead lines varies significantly based on multiple factors, including voltage level, power line type, supporting structure, geographical location, local regulations, and specific grid requirements.In urban areas, distribution utility poles are typically positioned at closer intervals, while in rural regions, they are spaced farther apart. Additionally, the use of taller structures for higher-voltage trans
Edwiin
06/05/2025
Synchronizing Power and Torque Coefficient
Synchronizing Power and Torque Coefficient
Definition of Synchronizing PowerSynchronizing power, denoted as Psyn, is defined as the variation in synchronous powerP with respect to changes in the load angle δ. Also referred to as thestiffness of coupling,stability factor, orrigidity factor, it quantifies a synchronous machine’s (generator or motor) inherent tendency to maintain synchronism when connected to infinite busbars.Principle of Synchronism MaintenanceConsider a synchronous generator transmitting a steady power Pa at a
Edwiin
06/04/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!