What is a Shunt Resistor?

A shunt resistor (or shunt) is defined as a device that creates a low resistance path to force most of the electric current through the circuit to flow through this path. In most cases, a shunt resistor is made up of a material having a low-temperature coefficient of resistance, giving it a very low resistance over a wide temperature range.

Shunt resistors are commonly used in current measuring devices called “ammeters”. In an ammeter, the shunt resistance is connected in parallel. An ammeter is connected in series with a device or circuit.

How Does a Shunt Resistor Work?

A shunt resistor has a low resistance. It provides a low resistance path to current, and it is connected in parallel with a current measuring device.

The shunt resistor uses ohm’s law to measure the current. The resistance of the shunt resistor is known. And it is connected in parallel with the ammeter. So, the voltage is the same.

Hence, if we measure the voltage across a shunt resistance, we can measure the current passing through the device by the equation below of ohm’s law.

  \[ I = \frac{V}{R} \]

Using a Shunt Resistor to Measure Current

Consider an ammeter that has resistance Ra and measures a very small current Ia. For exceeding the range of an ammeter, a shunt resistor Rs is placed parallel with Rm.

The circuit diagram of these connections is shown in the figure below.


image.png


The total current supplied by the source is I. It is divided into two paths.

According to Kirchhoff’s current law (KCL), 

 \[ I = I_s + I_a \]

Where,

Is = current passes through resistance Rs (shunt current)

Ia = current passes through resistance Ra

\[ I_s = I - I_a \]

The shunt resister Rs is connected parallel with resistor Ra. Hence the voltage drop across both resisters are equal.

  \[ V_s = V_a \]

\[ I_s R_s = I_a R_a \]

  \[ (I - I_a) R_s = I_a R_a \]

  \[ IR_s - I_a R_s = I_a R_a \]

  \[ IR_s = I_a R_a + I_a R_s \]

  \[ IR_s = I_a (R_a + R_s) \]

  \[ \frac{I}{I_a} = \frac{ R_a + R_s }{R_s} \]

  \[ N = 1 + \frac{R_a}{R_s} \]

Where N is a multiplying power of shunt.

How to Build a Shunt Resistor

The shunt resister can be built with very thin copper wires. The length and size of the shunt resister depend on the resistance you require.

The resistance of the shunt resistor will decide the range of the ammeter.

If you use 10 AWG (2.59 mm diameter) copper wire, the resistance of this wire is 0.9989 ohms per 1000 feet. This resistance may vary according to the quality of a wire.

Hence, make sure of the resistance before using it. To calculate the required length of wire for a particular value of shunt resistor, use the below equation.

  \[ Length \, of \, wire = \frac{Required \, shunt \, resistance \, (m \Omega)}{Resistance \, per \, 1000 \, feet }  \]

For example, if you require a shunt of 0.5 mΩ and use 10 AWG wire, put the above values in this equation.

  \[ Length \, of \, wire = \frac{0.5}{0.9989} \]

\[ Length \, of \, wire \approx 0.5 feet \]

What Is the Purpose of Shunt Resistor (Applications)?

The application of shunt resister is as listed below.

  • A shunt resistor is used in an electrical circuit to protect against overvoltage.

  • It is used in a current measuring device.

  • It is used to bypass defective devices. (When a number of components are connected in series, one component is failed to operate, it will break the entire circuit. In this condition, the shunt resistor bypasses the fail component and continues the circuit path.)

  • A shunt resistor with a capacitor is used in a circuit to avoid the problem of high-frequency noise.

  • It is used in overload protection control circuits, including power supplies.

How to Size a Shunt Resistor

Generally, a shunt resistor is used in the current measuring device. The size of the shunt resister will decide the range of the ammeter.

The size of the shunt resister depends on the maximum current rating. It is calculated by the voltage drop at the maximum current rating.

Let say a shunt resistor is designed for maximum current 100 A and voltage drop 50 mV. Typically, the voltage drop at maximum current is 50 mV, 75 mV, or 100 mV.

In this example, we can calculate the resistance of shunt resister by ohm’s law.


\[ V = I R \]

  \[ 50 \times 10^{-3} = 100 R \]

  \[ R = 0.5 m \Omega \]

Source: Electrical4u.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Electrical4u

Electrical4U is dedicated to the teaching and sharing of all things related to electrical and electronics engineering.

What is a Pure Resistive AC Circuit?
What is a Pure Resistive AC Circuit?
Pure Resistive AC CircuitA circuit containing only a pure resistanceR(in ohms) in an AC system is defined as a Pure Resistive AC Circuit, devoid of inductance and capacitance. Alternating current and voltage in such a circuit oscillate bidirectionally, generating a sine wave (sinusoidal waveform). In this configuration, power is dissipated by the resistor, with voltage and current in perfect phase—both reaching their peak values simultaneously. As a passive component, the resistor neither
Edwiin
06/02/2025
What is a Pure Capacitor Circuit?
What is a Pure Capacitor Circuit?
Pure Capacitor CircuitA circuit comprising only a pure capacitor with capacitanceC(measured in farads) is termed a Pure Capacitor Circuit. Capacitors store electrical energy within an electric field, a characteristic known ascapacitance(alternatively referred to as a "condenser"). Structurally, a capacitor consists of two conductive plates separated by a dielectric medium—common dielectric materials include glass, paper, mica, and oxide layers. In an ideal AC capacitor circuit, the current
Edwiin
06/02/2025
Resistance Switching in a Circuit Breaker
Resistance Switching in a Circuit Breaker
Resistance SwitchingResistance switching refers to the practice of connecting a fixed resistor in parallel with the contact gap or arc of a circuit breaker. This technique is applied in circuit breakers with high post-arc resistance in the contact space, primarily to mitigate re-striking voltages and transient voltage surges.Severe voltage fluctuations in power systems arise from two main scenarios: interrupting low-magnitude inductive currents and breaking capacitive currents. Such overvoltages
Edwiin
05/23/2025
What is Biot Savart Law?
What is Biot Savart Law?
The Biot-Savart Law is employed to determine the magnetic field intensity dHnear a current-carrying conductor. In other words, it describes the relationship between the magnetic field intensity generated by a source current element. This law was formulated in 1820 by Jean-Baptiste Biot and Félix Savart. For a straight wire, the direction of the magnetic field adheres to the right-hand rule. The Biot-Savart Law is also referred to as Laplace’s law or Ampère’s law.Conside
Edwiin
05/20/2025
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!